NWK99 Dielectric Electrical Maintenance Fluid
Developed by Nae Woi Korea for industrial switchboards, transformers, motors, and electronic enclosures. Removes conductive dust, oil, and moisture residue without conductive deposits.

Product — NWK99
Select grade to view application details and specifications

High-purity dielectric nanomaterial maintenance fluid engineered for switchboards, transformers, MCCs, motors, and HV/LV electrical equipment.
Conductive dust, moisture films, salt, and oil mist degrade electrical insulation and trap heat inside industrial cabinets. NWK99 OPP flushes contaminants cleanly from busbars, insulators, windings, and circuit breakers—restoring insulation resistance without disassembly or conductive residue.
- Dielectric Rating
- 35 kV (SGS EN 60156) · 80.1 kV Tested (K-Petro IEC 60156)
- Evaporation Residue
- 0 mg / 100 mL Dry Residue (ČSN ISO 759)
- Supply Formats
- 20 L (15.3 kg) Industrial Pail · 539 g Precision Aerosol
Characteristics
- High-dielectric formulation tested up to 80.1 kV (IEC 60156) for safe electrical maintenance workflows.
- Zero-residue evaporation removes oils, grease, carbon dust, and hygroscopic salts cleanly.
- Verified across 72-hour KETI motor and inverter PCB immersion testing without insulation damage.
Advantages
- Minimises strip-down maintenance time on switchboards, motors, and VFD cabinets.
- Reduces thermal blanketing by removing insulating layers of airborne dust and grime.
- Leaves a protective hydrophobic, anti-static barrier against moisture ingress.
- Non-corrosive to copper, metals, and standard insulating materials (Class 1 copper strip test).
Features
- Low surface tension penetrates tight busbar joints, breaker chutes, and stator windings.
- 66.0°C ± 1.0°C closed-cup flash point (EN ISO 2719) for safer industrial handling and transport.
- AU Inventory listed (AIIC / EVA00194) and compatible with pneumatic spray lance or aerosol use.
- Suitable for mining MCCs, power substations, water pumping panels, solar inverters, and manufacturing.
Technical Specifications (NWK99 OPP)
| Property | Measured Value | Test Reference |
|---|---|---|
| Dielectric Breakdown Voltage | 35 kV (SGS) · 80.1 kV (K-Petro) | EN 60156 / IEC 60156 (2.5 mm) |
| Volume Resistivity | 21,760 GΩ·m | SGS OCM / IEC |
| Dielectric Power Factor (60 Hz) | 0.000065 | SGS OCM / IEC |
| Relative Permittivity (ε) | 2.01 | SGS OCM / IEC |
| Dry Residue After Evaporation | 0 mg / 100 mL | ČSN ISO 759 (Report 2606912) |
| Flash Point (Closed Cup) | 66.0°C ± 1.0°C | EN ISO 2719 / ASTM D56 |
| Density at 15°C | 765.1 kg/m³ | EN ISO 12185 / ASTM D4052 |
| Water Content (Karl Fischer) | 0.003 % m/m | EN ISO 12937 |
| Copper Strip Corrosion | Class 1 (Non-Corrosive) | EN ISO 2160 |
| Active Immersion Endurance | 72 Hours Verified | KETI #2010-580F |
| Australian Chemical Status | Listed on AIIC Inventory | AICIS EVA00194 |
Documentation & Reports
ANZ Safety Data Sheet (SDS) and commercial supply enquiries are available directly via info@nwkanz.com.
NWK ANZ Enquiries
For NWK99 technical enquiries, documentation requests, or supply across Australia and New Zealand, send us a message or write directly to our email address below.